KVA GRID Southeast Asia

Southeast Asia · 20–2000 kVA

Used diesel generators, 20–2000 kVA, delivered to Southeast Asian ports

KVA Grid supplies inspected used generating sets from stock to projects across Southeast Asia, in 50 Hz and 60 Hz builds, with the voltage, enclosure and tank set for the destination. There is no online checkout and no published price: send the rating, the load and the port, and a written quotation follows within 24 hours.

  • Every unit is photographed where it stands and carries its own parameter table, serial number and test record.
  • 20 kVA to 2000 kVA, prime or standby duty, 50 Hz at 1500 rpm or 60 Hz at 1800 rpm.
  • Canopy, containerised, trailer-mounted and open-frame builds, with IP54 and C5-M paint for coastal sites.
  • EXW, FOB or CIF to Laem Chabang, Hai Phong, Jakarta, Port Klang, Manila and Singapore.

Range

Power range
20–2000 kVA
Condition
Used, inspected
Frequency
50 Hz / 60 Hz
Quotation
Within 24 hours
Terms
EXW / FOB / CIF
Warranty
12 months or 1000 h

What each market actually runs on

The set is built around the supply it has to sit behind, so the voltage and the frequency are decided before anything else. These are the standard low-voltage supplies across the region; confirm the site figure before ordering, because the alternator winding and the control panel are made to it.

Low-voltage supply values as published by each utility. Where a site runs at 380 V, 415 V or 440 V, say so in the enquiry: it changes the alternator winding.
MarketUtilityVoltageFrequencySet speedMain ports
ThailandMEA (Bangkok) / PEA (provinces)230/400 V50 Hz1500 rpmLaem Chabang, Bangkok
VietnamEVN220/380 V50 Hz1500 rpmHai Phong, Cat Lai, Cai Mep
IndonesiaPLN220/380 V50 Hz1500 rpmTanjung Priok, Tanjung Perak, Belawan
MalaysiaTNB240/415 V50 Hz1500 rpmPort Klang, Pasir Gudang, Penang
PhilippinesMeralco / NGCP230/400 V (220/440 V on older networks)60 Hz1800 rpmManila, Subic, Cebu
SingaporeSP Group230/400 V50 Hz1500 rpmSingapore
Cambodia, Laos, MyanmarEDC / EDL / YESC230/400 V50 Hz1500 rpmSihanoukville, Vientiane, Yangon

Built for the climate, not for a catalogue

Southeast Asian sites are hot, humid and often coastal. Those three conditions decide the rating, the enclosure and the paint more than the hour meter does.

Ambient

Derated for 40 °C, not 25 °C

ISO 8528 ratings are referenced to 25 °C. Plant rooms here run at 35–40 °C, so the figure in your quotation is the derated output at the site temperature, not the nameplate number.

Humidity

Anti-condensation heaters and IP54

At 80–90 % relative humidity an idle set collects water in the alternator. Heaters, sealed cable entries and IP54 enclosures are specified for this region as a matter of course.

Salt air

C5-M paint for coastal and island sites

Ports, coastal yards and islands attack steelwork. Canopies and frames can be supplied with ISO 12944 C5-M coating, stainless fasteners and a galvanised base tank.

Noise

Canopy builds for a site boundary

Hotels, hospitals and shophouses sit close to the fence line. Silent canopies are quoted with a dB(A) figure at 7 m, so it can be checked against the local limit before the order.

Frequency

60 Hz for the Philippines

The Philippines runs at 60 Hz: the set turns at 1800 rpm and takes a different alternator. Name the frequency in the first message, because it cannot be changed after the set is built.

Spares

Parts quoted from the serial number

Filters, belts and hoses are quoted from the set serial number and the engine model, so the part that arrives matches the machine on site rather than a similar one.

What is in the range

Sets are listed by power class, and each class page shows every unit currently in stock with its own parameters. Units change weekly, so the pages are the live list.

ClassRatingTypical dutyUnits in stock
100 kVA80 kW at 0.8 pfOne building, one critical busSee units →
200 kVA160 kW at 0.8 pfSmall hotel, clinic, workshopSee units →
300 kVA240 kW at 0.8 pfOffice building, retailSee units →
400 kVA320 kW at 0.8 pfData room, cold storeSee units →
500 kVA400 kW at 0.8 pfFactory line, hospital blockSee units →
800 kVA640 kW at 0.8 pfPlant, resort, campusSee units →
1000 kVA800 kW at 0.8 pfIndustrial site, data hallSee units →
2000 kVA1600 kW at 0.8 pfUtility-scale standby, parallel plantSee units →

Four configurations

Silent

Canopy

Weatherproof acoustic canopy with an integral base tank. The usual build for hotels, hospitals and city sites.

Container

Containerised

ISO footprint with walk-in access, for multi-set plants and sites where the set must travel and be installed the same week.

Mobile

Trailer mounted

Road-towable set for construction, events and rental fleets, with lights, brakes and a lifting frame.

Open

Open frame

Bare set for a permanent plant room with its own ventilation, exhaust and cabling already designed.

From enquiry to commissioning

Five steps, each one ending in a document rather than a promise.

  1. The briefRating in kVA and the duty, voltage and frequency, the largest motor on site, the ambient temperature and the destination port.
  2. The quotationConfiguration, engine and alternator make and model, price, lead time and delivery term, in writing within 24 hours.
  3. Inspection and testThe set can be inspected before it ships. Load bank test at the agreed rating, with the readings recorded and witnessed testing on request.
  4. DeliveryEXW, FOB or CIF to the named port. Packing list, factory test report and the wiring diagram as built travel with the set.
  5. After deliverySpares and service by serial number, and a warranty of 12 months from the ex-works date or 1000 running hours, whichever comes first.

Questions from buyers in the region

Can you supply a 60 Hz set for the Philippines?

Yes. 60 Hz builds run at 1800 rpm and are wound for 230/400 V or 220/440 V, which covers Meralco and the older networks. Say 60 Hz in the first message, because the frequency is fixed by the engine speed and cannot be changed after the set is built.

What does a used set include?

A used set, offered as an individual unit with its own parameter table, serial number and photographs of that machine. The condition, the hours and any works recommended before it goes into service are confirmed in the quotation, and the set can be inspected before it ships.

How is the price calculated if nothing is published?

From the configuration: the enclosure, the tank and autonomy, the control panel, whether an ATS is included, and the delivery city. Those change the number more than the base set does. Payment is 30 % with the contract and 70 % before shipment.

Do you deliver CIF to a Southeast Asian port?

Yes. EXW, FOB and CIF are all quoted, with the named place or port written into the quotation, together with the weights, dimensions and lifting points so the forwarder can plan the move.

What about import certification in Thailand, Indonesia or Malaysia?

Certification is a destination requirement, not something a supplier can assume. Sets are rated and tested to ISO 8528, IEC 60034 and IEC 60204-1, and the documents that travel with each set are listed on this site. Tell us the port and the tender clause, and the quotation lists what can be supplied for that market.

Who answers, and in which language?

The sales desk answers in English and Chinese, and messages in Arabic are answered in Arabic. WhatsApp is the fastest route for a question about a rating or a lead time; email is the fastest route for a load list or a tender extract.

Send the rating, the voltage and the port.

Four facts are enough for a written quotation: the rating in kVA, the voltage and frequency, the largest motor on site, and the destination port. The reply carries the configuration, the price and the lead time.

WhatsApp